Publications of P Chang
All genres
Journal Article (9)
1.
Journal Article
80 (6), pp. 2311 - 2325 (2018)
Compressed sensing for high‐resolution nonlipid suppressed 1H FID MRSI of the human brain at 9.4T. Magnetic Resonance in Medicine 2.
Journal Article
183, pp. 336 - 345 (2018)
MultiNet PyGRAPPA: Multiple neural networks for reconstructing variable density GRAPPA (a 1H FID MRSI study). NeuroImage 3.
Journal Article
31 (12), pp. 1 - 14 (2018)
Over‐discretized SENSE reconstruction and B0 correction for accelerated non‐lipid‐suppressed 1H FID MRSI of the human brain at 9.4 T. NMR in Biomedicine 4.
Journal Article
80 (2), pp. 442 - 451 (2018)
Non-water-suppressed 1H FID-MRSI at 3T and 9.4T. Magnetic Resonance in Medicine 5.
Journal Article
80 (1), pp. 380 - 390 (2018)
Constrained optimization for position calibration of an NMR field camera. Magnetic Resonance Imaging 6.
Journal Article
168, pp. 211 - 221 (2018)
High and ultra-high resolution metabolite mapping of the human brain using 1H FID MRSI at 9.4T. NeuroImage 7.
Journal Article
79 (2), pp. 1145 - 1156 (2018)
A comparison of optimization algorithms for localized in vivo B0 shimming. Magnetic Resonance in Medicine 8.
Journal Article
79 (1), pp. 529 - 540 (2018)
Modeling real shim fields for very high degree (and order) B0 shimming of the human brain at 9.4 T. Magnetic Resonance in Medicine 9.
Journal Article
186, pp. 1 - 8 (2013)
The dual role of Parylene C in chemical sensing: Acting as an encapsulant and as a sensing membrane for pH monitoring applications. Sensors and Actuators B: Chemical Conference Paper (1)
10.
Conference Paper
An active TX/RX NMR probe for real-time monitoring of MRI field imperfections. In: IEEE Biomedical Circuits and Systems Conference (BioCAS 2013), pp. 194 - 197. IEEE Biomedical Circuits and Systems Conference (BioCAS 2013), Rotterdam, The Netherlands, October 31, 2013 - November 03, 2013. IEEE, Piscataway, NJ, USA (2013)
Meeting Abstract (12)
11.
Meeting Abstract
Whole Brain High Resolution Metabolite Mapping Using 1H FID MRSI with Dynamic B0 Shimming at 9.4T. In MRS Workshop 2018 Metabolic Imaging, 14. MRS Workshop 2018 Metabolic Imaging, Utrecht, The Netherlands, October 02, 2018 - October 05, 2018. (2018)
12.
Meeting Abstract
Dynamic B0 Shimming for Multi-Slice Metabolite Mapping at Ultra-High Field in the Human Brain: Very High Order Spherical Harmonics vs. Multi-Coil. In Joint Annual Meeting ISMRM-ESMRMB 2018, 0833. Joint Annual Meeting ISMRM-ESMRMB 2018, Paris, France. (2018)
13.
Meeting Abstract
Whole Brain High Resolution Metabolite Mapping Using 1H FID MRSI with Slice-wise B0 Shim Updating at 9.4T. In Joint Annual Meeting ISMRM-ESMRMB 2018, 0619. Joint Annual Meeting ISMRM-ESMRMB 2018, Paris, France. (2018)
14.
Meeting Abstract
30 (Supplement 1), pp. S683 - S684. 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017), Barcelona, Spain. (2017)
ConsTru: an optimal B0 shimming solution. In Magnetic Resonance Materials in Physics, Biology and Medicine, 15.
Meeting Abstract
30 (Supplement 1), p. S112 - S112. 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017), Barcelona, Spain. (2017)
Over-discrete SENSE and B0 correction for accelerated 1H FID MRSI of the human brain at 9.4T. In Magnetic Resonance Materials in Physics, Biology and Medicine, 16.
Meeting Abstract
Fast non-water suppressed metabolite cycled 1H FID MRSI at both 3T and 9.4T. In 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), 1250. 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA. (2017)
17.
Meeting Abstract
High resolution maps of individual macromolecule components in the human brain at 9.4T. In 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), 1059, p. 619 - 619. 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA. (2017)
18.
Meeting Abstract
Pushing the limits of ultra-high field MRSI: benefits and limitations of 9.4T for metabolite mapping of the human brain. In 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), 1248, p. 723 - 723. 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA. (2017)
19.
Meeting Abstract
Multi-slice metabolite mapping with Very-High Degree Dynamic B0 Shim Updating at 9.4T using Accelerated 1H FID MRSI. In 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), 0971, p. 571 - 571. 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA. (2017)
20.
Meeting Abstract
Very High-Order B0 Shimming for Ultra-High Field Magnetic Resonance. In ISMRM Workshop on MR Spectroscopy: From Current Best Practice to Latest Frontiers. ISMRM Workshop on MR Spectroscopy: From Current Best Practice to Latest Frontiers, Allensbach-Hegne, Germany, August 14, 2016 - June 17, 2016. (2016)