Contact

Tamas Borbath

Address: Max Planck Ring. 11
72076 Tübingen
Room number: 1.B.09
Phone: +49 7071 601 1725
Fax: +49 7071 601 702
E-Mail: Tamas.Borbath

 

Picture of Borbath, Tamas

Tamas Borbath

Position: PhD Student  Unit: Henning Scheffler

I am a PhD student with a background in Computer Science. I am motivated by this Ph.D. project by the fact that we are developing cutting-edge techniques, which should help in the long-term other citizens, who by our technological improvements could have a better life.

 

My project aims at creating a software platform to post-process multi-modal MRI data. Furthermore, my project is aiming to improve the quantification of the Magnetic Resonance Spectroscopy data.

Ph.D. Project: Software Development for MRS module/Clinical Decision Support System

 

The aim of this project is to create a software solution to integrate Magnetic Resonance Spectroscopy (MRS) data processing within the CDS-QuaMRI EU-Project. An important part of the processing of MRS data is the quantification of the metabolites. Since with the MRS technique we are able to detect a “fingerprint” of the metabolism, it is also important to be able to assess what metabolites are present in which concentrations in the different brain regions. To achieve this quantification, a so called fitting software is needed, which should be designed in this Ph.D. project to become a versatile tool.

 

The CDS-QuaMRI project:

 

My Ph.D. project is funded by the EU-project CDS-QuaMRI. The aim of this EU-project is to create a clinical decision support software which connects different Magnetic Resonance Imaging (MRI) modalities to allow a quantitative processing of the data. This software should provide a modality to study the causes and neurological behavior of diseases, which are more difficult to diagnose currently with single modalities. The study shall be tested on patients suffering from major depressive disorder (MDD) and multiple sclerosis (MS).

The project is a joint effort of (see also figure 1):

1. Charite Berlin: contributing with multimodal patient data

2. University College London: contributing with existing multimodal patient data, relaxometry and diffusion weighted imaging (DWI) measurements. These techniques provide information about the anatomical structure of the brain.

3. Leiden University Medical Center: provides the arterial spin labeling sequence. This technique can quantify the perfusion (blood distribution) in the brain.

4. Universitätsklinikum Tübingen: provides methods for post-processing anatomical data and quantification methods for functional-MRI (fMRI) processing. The fMRI searches for activation regions in the brain, observed at resting state or when a given stimuli are used. Of special interest is the functional connectivity of brain regions.

5. Max-Planck Institute for Biological Cybernetics in collaboration with the University of Greifswald: contributes with methods for MRS data analysis. MRS allows the quantification of the metabolism and hence also of the healthiness state of brain tissue.

6. Eidgenössische Technische Hochschule Zürich: aims at developing a technique to classify the multi-modal data, acquired in Berlin and London and processed with the tools of the other sites, to distinguish based on characteristic features healthy subjects from patients. Machine learning will be the technique used for this.

7. GyroTools: this company will offer a software platform for the multi-modal quantification software. This software will create both interfaces to the MRI hardware, but also provide the software engineering design to integrate the different modalities.

 

Figure 1:

The project is constructed using several existing software solutions provided in a heterogeneous format from the different sites. Hence the software engineering is rather complex, but it has the advantage of integrating tested algorithms developed during the long term.

My contribution sides on the co-development of the software engineering structure with GyroTools, and restructuring and integrating the existing spectroscopy scripts into the final software solution.

 

MRS Fitting

 

In a magnetic field, atoms interact and this interaction creates chemical shifts of the different nuclei within a molecule. This phenomenon is used in MRS and this way we can visualize spectra, which represent peaks or a set of peaks, which reflect the molecular structure and abundance of metabolites in a given volume of interest. The knowledge of the chemical shifts and other properties allow us to distinguish the different metabolites present in the brain. By evaluating the properties, which are seen by the metabolites and solving an optimization problem we can evaluate the concentration of given metabolites. This process is called fitting.

In this fitting process, a good software has to consider artifacts, account for lipid signals, or for so called macromolecular signals, which originate mainly from amino acids.

We both investigate the fitting of 1-dimensional spectra (figure 2.A) and spectra which are resolved in a second dimension, like the J-sLASER spectra (figure 2.B). A long term objective is to fit spectroscopy imaging (MRSI) data, which captures the spatial distribution of the metabolites in the brain. The challenge is to mitigate the worse spectral quality of individual voxels by spatial prior knowledge. Figure 2.C shows how artifacts and lipids can affect the spectral fitting, hence a robust algorithm has to be developed.

 

Figure 2:

Another aspect investigated in the fitted concentrations is the effects of the origin and composition (gray or white matter richness) of the macromolecular baseline used for fitting (See figure 3).

 

Figure 3:

Current

Max Planck Institute of Biological Cybernetics (KYB)

2016-Current

Computational Science/MR Engineer (PhD Student)

Department of High-field Magnetic-Resonance Group

Research group of MR Spectroscopy and Ultra-High Field Methodology

Project: Software Development for MRS Module / Clinical Decision Support System

 

Education

Technical University Munich (TUM)

2013-2015

M.Sc. hons. in Computational Science and Engineering (CSE)

Department of Computer Science

Thesis: Software Enhancement Tools for Magnetic Resonance Spectroscopy

 

Transilvania University of Braşov (UnitBv)

2009-2013

B.Sc. (Eng) in Computers

Department of Electrical Engineering and Computer Science (IESC)

Thesis: Image processing on an embedded system for traffic control cameras

 

Ruhr-Universität Bochum (RUB)

2011-2012

Exchange student with majors in Information Technology, Cryptography and Embedded Systems

Department of Electrical Engineering and Information Technology(ETIT)

 

Áprily Lajos High School, Braşov, Romania

2005-2009

 

Work Experience

General Electric Global Research (GEGRC-Munich)

2014-2015 (8 + 8 months)

Student Project + Intern Software Developer

Description: Developed a software framework, worked on the graphical user interface and the software back-end of a Magnetic Resonance Spectroscopy tool.

 

Technical University Munich – Chair of Scientific Computing (SCCS)

2014 (5 months)

Academic Course Tutor

Description: Tutored the graduate course Advanced Programming.

 

Technical University Munich – Institute of Micro Technology and Medical Device Technology (MIMED)

2014 (3 months)

Research Assistant

Description: Developing image processing algorithms for 3D endoscopy images.

 

Technical University Munich – Chair of Computer Technology and Computer Organization (LRR)

2014 (3 months)

Research Assistant

Description: Programming BLAS routines for FPGAs.

 

Preferences: 
References per page: Year: Medium:

  
Show abstracts

Posters (2):

Borbáth T, Giapitzakis IA, Murali Manohar SV and Henning A (April-27-2017): Fitting comparison for 9.4T 1D semi-LASER and 2D-J-resolved semi-LASER data, 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA.
Murali Manohar SV, Giapitzakis IA, Borbáth T, Gaertner M and Henning A (April-27-2017): Qualitative Comparison between In Vivo J-Resolved Semi-LASER at 3 T and 9.4 T, 25th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2017), Honolulu, HI, USA.

Talks (2):

Borbáth T, Giapitzakis I, Murali Manohar SV and Henning A (October-19-2017) Abstract Talk: Do macromolecular and spline baselines affect the metabolite quantification at 9.4T?, 34th Annual Scientific Meeting of the European Society for Magnetic Resonance in Medicine and Biology (ESMRMB 2017), Barcelona, Spain, Magnetic Resonance Materials in Physics, Biology and Medicine, 30(Supplement 1) S115-S116.
Coello E, Janich M, Schirmer T, Noeske R, Borbath T, Haase A and Schulte R (May-10-2016) Abstract Talk: Overdiscrete Reconstruction in Echo-Planar Spectroscopic Imaging with Auto Calibrated B0 Field Map Estimation, 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016), Singapore(386).

Export as:
BibTeX, XML, Pubman, Edoc, RTF
Last updated: Monday, 22.05.2017